Regular testing and calibration of various gas alarms in the workplace

SINO Testing Services

| 2025-01-06|Return

Shenzhen Zhongnuo Detection Technology Co., Ltd. specializes in the detection, calibration, measurement and other services of gas alarms, combustible gas detectors, toxic and harmful gas detectors and other equipment in various places. With complete qualifications, we serve the whole country and solve various electrical and explosion-proof fire problems for our customers.

Testing regulations and requirements of relevant standards:

According to Article 5.5 of the Verification Regulations for Combustible Gas Alarm Devices (JJG693-2011), the calibration cycle for combustible gas detection and alarm devices is generally not more than one year. If there are doubts about the measurement data of the instrument, or if the main components of the instrument are replaced or repaired, it should be promptly sent for inspection.

According to Article 3.5 of the "Specification for the Use of Combustible Gas Detection and Alarm" (SY6503-2000), combustible gas detection and alarm devices in use should be calibrated regularly according to regulations

According to Article 7.2.1 of the "Specification for the Installation of Toxic Gas Devices in the Workplace" (GBZ/T223-2009), the detection and alarm devices shall be calibrated regularly according to the manufacturer's specified time and procedures.

According to Article 3.4 of the "Specification for the Use of Combustible Gas Detection and Alarm Devices" (SY6503-2000), the combustible gas detection and alarm devices installed and used should be manufactured with measuring instruments recognized by national institutions and have explosion-proof performance**


Testing items:

1. Installation spacing of inspection (probing) points

2. Installation height of the detector (probe)

3. Indication error (concentration)

4. Repeatability (concentration)

5. Alarm error (concentration)

6. Response time (seconds)


Testing standards:

GB/T50493-2019 "Design Standard for Combustible Gas and Toxic Gas Detection and Alarm in Petrochemical Industry"

GB12358-2006 General Technical Requirements for Workplace Gas Detection and Alarm Devices
JJG693-2011 "Verification Regulations for Combustible Gas Detection and Alarm Devices"

Detection object:Various types in useFixed installation, handheld, portableGas alarm, gas alarm, toxic and harmful gas detector/alarm, combustible gas detector/alarm, gas detector, etc.

Testing method: on-site testing

Quotation data requirements:
1. Distribution diagram and quantity of equipment locations
2. Types of gas detectors (what types of gases are detected)



Related Recommendations
Contact us
0755-2102 2109
Add: 13F, Building C, Kangjia Guangming Technology Center, No. 288 Xingxin Road, Guangming District, Shenzhen
Follow us
Copyright: Shenzhen Zhongnuo Testing Technology Co., Ltd. 粵ICP備18004888號(hào)
Service Hotline
18924609560
點(diǎn)擊這里給我發(fā)消息 1354407946
點(diǎn)擊這里給我發(fā)消息 1354407946
主站蜘蛛池模板: 国产床上视频 | 日本xxx网站 | 久久www免费人成_看片高清 | 国产成人aa免费视频 | 欧美一区二区三区gg高清影视 | jizz国产在线播放 | 国产拍揄自揄精品视频网站 | 久久久久久亚洲精品不卡 | 麻豆a| 99久久精品国产国产毛片 | 亚洲国产品综合人成综合网站 | 日本三级网络 | avwww在线| 欧美三级在线播放 | 国产综合婷婷 | 免费行情网站推荐 | 久久亚洲国产精品五月天婷 | 日本高清专区一区二无线 | 亚洲一区日本 | 青娱乐极品视频在线观看 | 久久青娱乐 | 两个人看的在线观看视频www | 欧美伊人影院 | 久久久久久影视 | 欧美一区二区三区不卡 | 看全色黄大色大片免费久久久 | 久久伊人中文字幕 | 精品五月天 | 天天爱天天操天天射 | 久久亚洲精品中文字幕二区 | 国产欧美又粗又猛又爽老 | 久草视频福利资源站 | 日本黄色小视频网站 | 欧美视频综合 | 欧美精品一区二区三区免费播放 | 欧美视频在线免费 | 亚洲午夜大片 | 亚洲天堂中文网 | 久久综合九色综合网站 | 日本高清一二三区 | 久久丁香视频 |